Asenware AW-CFP2166 16 Zone Conventional Fire Panel
The Asenware AW-CFP2166 16 Zone Conventional Fire Alarm Panel is a robust and reliable fire detection control unit designed in compliance with EN54 Part 2 & Part 4 standards. This panel serves as the central component of a conventional fire alarm system, supporting a wide range of fire detection and alarm devices such as smoke detectors, manual call points, sounders, and sprinkler supervision. Engineered for both small and large-scale fire protection systems, it supports up to 16 zones, making it ideal for commercial buildings, industrial facilities, offices, and multi-level complexes.
Product Features
EN54 Part 2 & 4 Compliant
Fully compliant with European fire safety standards for fire detection and alarm control panels, ensuring high reliability and regulatory approval.
Expandable Zone Capacity
Standard unit supports 8 zones, expandable up to 16 zones to meet the needs of larger applications and complex installations.
Manual Zone Isolation
Each zone can be individually disabled using dedicated control buttons, allowing for flexible system management during maintenance or testing.
High Power Output
Equipped with a powerful internal 27.2VDC power supply and 3A total output at 220VAC for consistent device performance.
Integrated Battery Backup
Includes two 12V 2.3Ah batteries for automatic operation during mains failure, maintaining system integrity in emergencies.
Multiple Circuit and Output Options
Supports 12–32 circuits and includes both NC and NO relay outputs for system integration and control versatility.
Durable Construction
Built with high-quality components and housed in a sturdy steel enclosure to ensure long-term durability in demanding environments.
Product Specifications
- Mains supply voltage: 110VAC or 220VAC
- Internal power supply: 27.2VDC
- Total output current (limited): 3A @ 220VAC
- Battery backup: 2 x 12V 2.3Ah
- Number of circuits: 12 to 32
- End of line device: 6.8kΩ ±5%, 0.5–1W (color code: blue, grey, red, gold)
- Call point resistor value: 470 to 680Ω, 0.5 or 1 watt
- Number of general circuits: 2
- Output protection:
- Outputs fused at 600mA
- Sounder outputs: 750mA resettable fuse
- Battery fuse: 1.85A resettable fuse
- Output type: Normally Closed (NC) and Normally Open (NO) relay
- Maximum output current: 100mA
- Bell capacity: Up to 30 bells @ 50mA each per sounder output
- Conductor size range:
- Max: 2.5mm²
- Min: 0.75mm²
- Dimensions: 640mm x 390mm x 150mm
- Weight (with batteries): 13 kg