Asenware AW-CFP2166-08 8-Zone Conventional Fire Alarm Control Panel
The Asenware AW-CFP2166-08 is a high-performance 8-zone conventional fire alarm control panel engineered to meet EN54 Part 2 and Part 4 standards. Designed for dependable fire detection and alarm monitoring, this panel supports a wide range of devices including smoke detectors, manual call points, bells, and sprinkler systems. With modular expandability, dual power modes, zone disabling, and optional GSM communication, it provides a complete and scalable solution for commercial, industrial, and institutional applications.
Product Features
Modular Design with Zone Expandability
Supports configurations from 1 to 32 zones, making it adaptable for both small buildings and larger premises requiring more complex fire detection coverage.
Two-Level Access Control
Provides secure operation through a key lock mechanism, ensuring only authorized personnel can access control functions.
Multi-Voltage Power Supply
Operates with mains supply of either 110VAC or 240VAC, and internally delivers a stable 27.2VDC output to power connected devices.
High Output Current Capacity
Delivers a total output current of up to 3A at 240VAC, supporting various external components such as sounders, indicators, and relays.
Integrated Fire and Fault Signal Outputs
Equipped with dedicated outputs to notify auxiliary systems in case of fire or system fault, enabling external alerts and automated responses.
Dual General Sounder Circuits
Provides two 24VDC sounder outputs, each capable of driving up to 500mA, for reliable audible warning distribution throughout the building.
Independent Detector Inputs
Each of the 8 zones supports one dedicated circuit for smoke or heat detectors, manual call points, or other initiating devices.
Manual Zone Disabling
Individual zone disable functionality allows for targeted maintenance or isolation without compromising the rest of the system.
Manual Panel Reset
Features a one-touch RESET function to return the system to normal operating mode after alarm or fault conditions have been addressed.
Sounder and Buzzer Silence
A SILENCE button disables both the internal panel buzzer and external sounders during alarm verification or troubleshooting.
Manual Evacuation Activation
The EVACUATE button allows immediate manual activation of alarms across all zones for fast response in emergencies.
Battery Backup with Low Voltage Cutoff
Includes battery protection circuitry that disconnects backup batteries if voltage drops below 21VDC, ensuring safe operation and preserving battery health.
Optional GSM SMS Alerts
Supports an optional GSM communication module for sending fire alarm notifications via SMS to designated contacts or monitoring centers.
Product Specifications
- Item: 8 Zone Fire Alarm Control Panel
- Model No.: AW-CFP2166-04-16
- Zones Supported: 8 zones (expandable to 32 with modules)
- Compliance: EN54 Part 2 and Part 4
- Mains Supply Voltage: 110VAC or 240VAC
- Internal Power Supply: 27.2VDC
- Total Output Current: Up to 3A @ 240VAC
- Backup Batteries: 12V 2AH × 2 = 24VDC (default configuration)
- Sounder Outputs: 2 × 24VDC, 500mA max each
- Detector Inputs: 1 circuit per zone
- End of Line Device: 6.8kΩ, 5% tolerance, 0.25W (color code: blue, grey, red, gold)
- End of Line Resistor Value: 6.8kΩ, 22.5% tolerance, 0.25W
- Fire and Fault Relay Outputs: Included
- Panel Dimensions: 395 × 502 × 124 mm
- Weight (Without Batteries): 7 kg
- Weight (With Batteries): 9.6 kg
- Environmental Class: Class A
- Operating Temperature: -5°C to +50°C
- Humidity Range: 5% to 95% RH, non-condensing
- Optional Features: GSM module for SMS alerts
- Protection Functions: Battery low voltage cutoff, zone disable, system test